<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-09 20-12-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 59 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 23 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
17 kHz 74 kHz 10018 3,9030
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,7 dBr 8,08 dBr 8,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 20:12, 9.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (58 dBuV) Max at: 74 kHz MIN: 17 kHz % above 75 kHz: 3,9030 Acquired: 2025/01/09 20:11:16 Total samples: 10018 Equivalent time: 0:08:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,4 dBr MIN: 7,7 dBr AVE: 8,08 dBr % above 10,0 dBr: 0,0 Last value: 7,8 dBr (2025/01/09 20:11:15) Station: 96.90 MHz, signal: 4/5 (56 dBuV) 20:04 20:05 20:06 20:07 20:08 20:09 20:10 20:11 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality